Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T02CM01052
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2002 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
| 02/27/2002 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999*/ 1) FOUNDATION APPEARS TO BE TO SHALLOW ON 6" BELOW GRADE, PHOTOS INDICATE ONLY A #3 OR #4 REBAR IN FOOTING. EXPOSE FOOOTING AROUND ENTIRE SLAB. PROVIDE CITY OF TUCSON APPROVED DETAIL FOR PROVIDING PROPER FOOTING 2) GAS LINE CANNOT BE UNDER SLAB-CAP AND ABANDON AND REROUTE 3) UNDER SLAB D.W.V. PLUMBING IS NOT PER CODE. SANITARY "T" FITTINGS NOT ALLOWED IN THE HORIZONTAL POSITION-W/C HEAL VENTED. REPLACE ALL UNDER SLAB D.W.V. PLUMBING |