Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM01044
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
04/02/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) SIMPSON #US26 HANGERS USED AT GARAGE GIRDER ARE NOT NAILED PER SIMPSON REQUIREMENT. THIS IS THE FOURTH TIME THIS HOUSE HAS FAILED FOR THE SAME REASON. ANOTHER RE-INSPECTION FEE HAS BEEN ADDED | |
03/26/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) AHUS HANGERS NOT NAILED PER SIMPSON REQUIREMENT 2) A RE-INSPECTION FEE HAS BEEN ATTACHED TO THIS PERMIT | |
03/25/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) SEE ITEMS TWO AND THREE FROM PREVIOUS INSPECTION DONE ON 3/20/02 | |
03/20/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) STRAP HEADERS PER DETAIL (SD/602) 2) AHUS HANGERS MUST BE NAILED WITH MINIMUM 10D NAILS DRIVEN AT 45 DEGREE ANGLE 3) TRUSS BRACING NOT PER PLAN. SEE DETAIL (SD/413) 5) SHEAR AT REAR NOT NAILED |