Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM01038
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/02/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/26/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) AHUS HANGERS STILL NOT PROPERLY NAILED 2) A RE-INSPECTION FEE HAS BEEN ATTACHED TO THIS PERMIT | |
03/25/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) SEE ITEMS ONE AND FOUR FROM PREVIOUS INSPECTION DONE ON 3/20/02 | |
03/20/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) TRUSS GABLE BRACING NOT PER PLAN SEE DETAIL (SD/413) 2) PROVIDE TRUSS CALC'S/DRAWINGS AT (00015) INSPECTION 3) STRAP HEADERS PER PLAN SEE DETAIL (SD/602) 4) SIMPSON AHUS HANGERS MUST BE NAILED AT 45 DEGREE ANGLE WITH MINIMUM 10D NAILS 5) CHIMNEY MUST BE STRAPPED THROUGH ROOF TO TRUSSES BELOW |