Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/02/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/26/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) AHUS HANGERS STILL NOT PROPERLY NAILED 2) A RE-INSPECTION FEE HAS BEEN ATTACHED TO THIS PERMIT |
| 03/25/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEE ITEMS ONE AND FOUR FROM PREVIOUS INSPECTION DONE ON 3/20/02 |
| 03/20/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) TRUSS GABLE BRACING NOT PER PLAN SEE DETAIL (SD/413) 2) PROVIDE TRUSS CALC'S/DRAWINGS AT (00015) INSPECTION 3) STRAP HEADERS PER PLAN SEE DETAIL (SD/602) 4) SIMPSON AHUS HANGERS MUST BE NAILED AT 45 DEGREE ANGLE WITH MINIMUM 10D NAILS 5) CHIMNEY MUST BE STRAPPED THROUGH ROOF TO TRUSSES BELOW |