Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/15/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/09/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) CROSS BRACE MID SPAN 2) SHEAR NAILING 3) STRAP NON-CABIN TIED TOP PLATES AND TRUSS CORNERS TO KINGS |
| 04/05/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) INADEQUATE SHEAR NAILING AT REAR (MAX SPAN 16" ON CENTER) 2) ADD MID-RIDGE BRACING ON TRUSSES 3) PLEASE CLIP OR STRAP BOX HEADERS AT BACK PORCH TO STRUCTURE |