Permit: T02CM01015

Parcel: 124050410

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T02CM01015

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
10/30/2002 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*
10/25/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED
10/24/2002 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*/ 1) NEED WATER TEST ON ALL SEWER PIPE, DISCONNECT AT MISSION COUPLING AND GAP, RETEST WITH A MINIMUM 10' WATER COLUMN 2) CLEAN OUT THAT EXTEND TO GRADE MAUST BE INSTALLED FOR EVERY 135 DEGREE CHANGE OF HORIZONTAL ANGLE 3) GLUE UP ALL BLAKE "T" CAPS