Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 09/30/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 09/19/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1.) 710.1 94 UPC DRAINAGE PIPING SEWING FIXTURES WHICH HAVE FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER... SHALL BE PROTECTED FORM BACKFLOW BY INSTALLING AN APROVED BACKWATER VALVE FIXTURES ABOVE SUCH ELEVATION SHALL NOT DISCHARGE THROUGH THE BACKWTER VAVLE. 2.) BECAUSE OF THE CLOSE PROIMITY OF FFE AND MANHOLE RIM ELEVATION, FLOOR SINKS AND FLOOR DRAINS WOULD DISCHARGE THROUGH THE BACKWATER VALVE, ALL OTHER FIXTURES WOULD NOT DISCHARGE THROUGH THE BACKWATER VALVE. PLEASE HAVE THE ENGINEER CLARIFY THIS MATTER AND REVISE PLAN IF NECESSARY BEFORE NEXT INSPECTION. 3.) 4" SDR FROM BLDG. EXCLUDING DIRECTIONAL CLEAN OUT THROUGH BACKWATER VALVE TO MANHOLE OK WATER TEST OK CONTINGENT ON BACKWATER VALVE APPROVAL 4.) OK TO COVER |