Permit: T02CM01004

Parcel: 133443690

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/19/2002 FRAMING Approved IVRS - Inspection 0000*
04/17/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) NEED TRUSS SPECS AND ADDITONAL DETAILS ( SHEET SD2) ? 2) STUD TO TERMINATE AT SPLIT OF BOTTOM PLATES 3) CHECK ALL HEADER SIZES 4) ALL REJECTED ITEMS NOT COVERED
04/12/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) INSTALL ALTERNATE HOLDOWN WHERE MAS NOT NIALED ONTO STUDS (SINGLE GARAGE) 2) STUD MISSING OVER BEARING HEADER BATHROOM 3) FILL SOLIDLY ALL HEADERS AT BEARING 4) FIREBLOCK MISSING UNTO STAIRWELL AND BEHIND WASHER BOX 5) INSTALL SOLID WOOD 1ST TO 2ND FLOOR AT GIRDER TRUSS BEARING POINTS 6) AT LEDGER SPLICE USE DOUBLE STUDS AND STRAP LEDGER WITH C320 X 18" STRAP 7) IF TRUSS SPAN 13'-1" TO 15'-0" INSTALL A35 EACH STUD TO LEDGER 8) BEDROOM STUD WAY OUT OF PLUMBING UPSTAIRS 9) SECURE RETURN AIR PLENIUM TO TRUSSES