Permit: T02CM00995

Parcel: 137340980


Addresses:

1416 W EUDORA PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/16/2002 FRAMING Approved IVRS - Inspection 0000*
04/10/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) RE: BACK PATIO NOT COMPLETE THIS WAS ADDED AFTER HOUSE WAS POURED AND ALL OTHER TRADES WERE DONE
04/09/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE SCREEN FROM DRYER VENT 2) REMOVE COMBUSTIBLES AWAY FROM FURNACE VENT FLUE 1" REQUIRED 3) EXHAUST FAN AT ALUNDRY ROOM NOT HOOKED UP 4) OK TO INSULATE REST OF HOUSE WILL NEED TO REINSPECT THESE THREE ITEMS BEFORE SHEET ROCK IS PUT ON 5) WILL APPROVE FRAMING WHEN ALL TRADES ARE COMPLETE
04/05/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE WATER TEST DWV 2) 1994 UPC SEC 1002.2 RE: TRAP ARM AT WASHER STAND PIPE 3) PROVIDE VENTING AT LAUNDRY ROOM 4) SHIM HEADERS THRU-OUT HOUSE 5) MOVE ELECTRICAL WIRES AWAY FROM CAN LIGHTS 6) EXHAUST FAN AT MASTER BATH MISSING FLAPPER 7) STOPPED INSEPCTION AT MASTER BATH AREA