Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/21/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/20/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) FLUSH UP NAILS IN GARAGE O.S.B. 2) STRAP TOP PLATES, OVER FRONT DOOR, TO INTERSECTION WALLS (ALL NON-CABIN TIED) 3) CLIP RIGHT REAR CORNER STUDS 4) STRAP TRUSS TO KING STUD AT SOUTH EAST PATIO CORNER 5) FHA STRAP PLATES AT PLUMBING CUTS 6) UN-NAIL SHEARWALL A.35 CONNECTION UNTIL ROOF IS LOADED |
| 03/18/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |