Permit: T02CM00988


Addresses:

4314 E 4TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
03/26/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
03/15/2002 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) MAKE UP ( CONNECT ALL GROUND WIRES TOGETHER IN ELECTRIC BOXES AND SECURE WITH A MECHANICAL FASTENER-WIRE NUT OR BUCHANAN) ALSO PROVIDE A GROUND PIG TAIL FOR EACH DEVICE) 2) YOU MUST PROVIDE PHYSICAL PROTECTION FURR ALL WIRES BELOW 8' ELEVATION ( BEHIND WALL COVERING OR IN CONDUIT. OK TO COVER WIRES BUT DO NOT INSTALL SWITCHES AND OUTLETS PRIOR TO NEXT INSPECTION 3) ELECTRIC SUB PANEL REQUIRES AN ISOLATED NEUTRAL BAR AND A SEPARATE GROUND BAR