Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/26/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 03/15/2002 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MAKE UP ( CONNECT ALL GROUND WIRES TOGETHER IN ELECTRIC BOXES AND SECURE WITH A MECHANICAL FASTENER-WIRE NUT OR BUCHANAN) ALSO PROVIDE A GROUND PIG TAIL FOR EACH DEVICE) 2) YOU MUST PROVIDE PHYSICAL PROTECTION FURR ALL WIRES BELOW 8' ELEVATION ( BEHIND WALL COVERING OR IN CONDUIT. OK TO COVER WIRES BUT DO NOT INSTALL SWITCHES AND OUTLETS PRIOR TO NEXT INSPECTION 3) ELECTRIC SUB PANEL REQUIRES AN ISOLATED NEUTRAL BAR AND A SEPARATE GROUND BAR |