Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/01/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL ELECTRIC OUTLETS IN GARAGE MUST BE GFCI PROTECTED. DOWN STREAM OUTLETS MUST BE CONNECTED TO LOAD SIDE OF OUTLET 2) ALL ELECTRIC WIRES BELOW 8' MUST BE PHYSICALLY PROTECTED. RECOMMEND COVER WITH DRYWALL |
| 02/27/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) GFCI OUTLETS REQUIRED IN GARAGE |
| 02/23/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0920*/ 1) NO ONE HOME 2) PROPERTY LOCKED 3) LOOSE DOG IN YARD 4) ELECTRIC PANEL OK |