Date Description Inspector Results Comments
04/26/2002 FRAMING Approved IVRS - Inspection 0000*
04/25/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) LOW GAS PRESSURE 816D'S 2) FHA STRAP TOP PLATES AT GAS MAIN 3) FILL ALL HOLES IN H2.5 CLIPS 4) TIGHTEN ALL RED HEADS 5) DWV TEST NOT FULL 6) STRAP ALL NON-CABIN TIED TOP PLATES ON EXTERIOR 7) FINISH H.D.'S INSTALL-ALL 8) SHIM HEADERS WHERE NEEDED