Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2004 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
| 08/20/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 08/17/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO PLANS/PERMIT 2) LEFT MESSAGE AT PHONE NUMBER LEFT ON RECORDING 3) RECALL FOR DUPLEX AS THIS IS CONNECTED WITH THAT PERMIT |
|
| 06/10/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : The sewer is not per code.| 305*/ CONFIRM HCS CONNECTION AT STREET. - MULTIPLE BLDG DRAINS INTO ONE SIX INCH SEWER. IS A JOINT SEWER AGREEMENT REQUIRED? REDUCING A 6" SEWER TO A 4" HCS IS CONSIDERED AN OBSTRUCTION OF FLOW. SINCE A 4" SEWER CAN HANDLE 216 DFU WHY WAS 6" INSTALLED? RICK - PLEASE SEE RANDY O'HAVER REGARDING A QUESTION HE HAD ON THE HCS CONNECTION. |
|
| 06/09/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED VERIFICATION OF 01005, 01015, 01035, 02035, 03035, 03050 AND 04035 INSPECTION APPROVALS |
|
| 08/14/2003 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*/NOT READY FOR INSPECTION. NOT TEST PLAN HAS BEEN APPROVED IN ERROR. PLEASE REFER TO 94 UPC SEWER SECTION |