Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/04/2002 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*1.) CROSS SLOPE OF ACCESSIBLE SIDE WALK TO BE NO MORE THAN 2% 2.) ADA PARKING SHOULD BE MAX 2% SLOPE IN ANY DIRECTION.
10/29/2002 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*THRESHOLD @ FRONT DOOR TO BE 1/4" MAX EDGE WITH 1:2 SLOPE FOR NEXT 1/2" 2.) "DOOR TO REMAIN UNLOCKED WHILE BUILDING OCCUPIED" 1" TALL LETTERS OVER FRONT DOOR. 3.) PROVIDE APPROVED FINAL INSPECTION REPORTS FROM ELECTRICAL AND PLUMBING INSPECTORS 4.) COMPLETE ADA SIGNAGE FOR RESTROOM. 5.) COMPLETE SITE WORK.