Permit: T02CM00857

Parcel: 136216900

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/11/2002 FRAMING Approved IVRS - Inspection 0000*
04/02/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CHANGE OUT HANGER NAILS 2) NEED SHEAR TRANSFER DETAIL GARAGE WALL PERPENDICUALAR TRUSS TO WALL SITUATION, NOT ON PLANS 3) 4 X 6 AT GIRDER E.P.C. HARDWARE 4) PEX WATER LINES 12" FROM WATER HTR FLUE 5) SECURE EXHAUST FAN DUCTS 6) CRIPPLE AT BATH WALL BEHIND TOILET EAST WALL 7) INSULATE AT TUBS FILL BLK OUT WITH CONC. 8) INSULATE RETURN BOX CEILING 9) PIPES OUT OF WALL KITCHEN 10) SECURE BOTTOM PLATE WEST BATH CLOSET 11) SMOKE DETECTORS REAR BEDROOM 12) USE 8D SLOTED TRUSS CLIPS