Permit: T02CM00856

Parcel: 136216860

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/11/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) HAVE DETAIL LABELED FOR SHEAR TRANSFER
04/02/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) MISSED ROOF NAILING AT DRYER DUCT (MARKED IN BLUE) 2) MAS H.D. NAILED TO OSB ONLY BACK WALL 3) NEED 4 X 6 POST GIRDER (SEE PLANS) TYPICAL BOTH SIDES (EPC) HARDWARE 4) TRUSS TO GIRDER USE 10D HANGER NAILS, NOT 8'S 5) SLOTTED TRUSS CLIPS USE 10D 6) EPC HARDWARE AT 4 X 6 POSTS