Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM00726

Parcel: 127130860


Addresses:

500 N PLACITA MIRA


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM00726

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/09/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
05/07/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
05/03/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) JAVIER NEEDS TO TALK TO ROB F.
04/30/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) FINISH NAILING ROOF
04/29/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) H3 CLIPS MISSING SEE 9/D-1 2) ST 2115 STRAPS MISSING SEE 13/D-1, CLIP ALL HEADERS PER 14/D-1 OR PROVIDE A SEPARATE APPROVED HEADER DETAIL 3) NO CITY APPROVED TRUSS DRAWINGS ON SITE TRUSSES DO NOT MATCH PLAN 4) ROOF SHEATHING MUST SPAN 2 BAYS, (3 TRUSSES)