Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/12/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/11/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) FRONT BEDROOM HAS NO CLOSET AND WINDOW SIZE DOES NOT ALLOW EGREE. PLAN MUST BE REVISED TO A DEN (NON SLEEPING ROOM) PER ITEM #3 OF 1/13/03 INSPECTION |
| 01/13/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) EXPOSE SILL PLATE ONE AREA 2) EXPOSE FOOTING TWO LOCATIONS AS SHOWN TO A DEPTH OF 12" 3) INADEQUATE GRESS FROM SOUTH EAST BEDROOM. ONE WINDOW MUST HAVE A MINIMUM OPENING OF 20" WIDE BY 24" HIGH WITH MINIMUM OPENING OF 5.7 SQUARE FEET 4) ELECTRIC OUTLETS REQUIRED WITHIN 6' EACH SIDE OF DOOR WAY AND EVERY 12 FEET THERE AFTER 5) BEDROOM REQUIRES A BAS BOARD HEATER ON A DEDICATED CIRCUIT 6) ELECTRIC SUB PANEL REQUIRES AN ISOLATED NEUTRAL BAR AND ADDED NEUTRAL WHITE #10 WIRE 7) COLOR CODE WHITE WIRE IN PANEL RED 8) ROOM IS NOT BEDROOM REVISE PLAN TO DEN |
| 01/08/2003 |
BUILDING - FINAL |
|
Prior to Final Inspectn |
INTERPUTER NEEDED FOR FINAL INSPECTION |