Permit: T02CM00637

Parcel: 12620001A


Addresses:

3455 E ZOO CT

Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
10/15/2004 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :*
06/04/2004 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*/ OK U.G. CONDUIT AND POLE BASES.
06/02/2004 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*/ OK FOUR POLE BASES NORTH EAST CORNER PRKG. OK REMAINDER OF U.G. CONDUIT HOMERUN TO BLD.
06/01/2004 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*/ OK EAST PARKING LOT SIT LTG.
03/12/2004 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ FOUR 4" SECONDARY CONDUITS FROM UT TR TO SES. APPROVED UNDERGROUND.
02/06/2004 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*
12/23/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ MCC-2 UNDERGROUND APPROVED.
12/17/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*
12/12/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ LOCKER ROOMS UNDERGROUND APP. TENT STAKE MOCK UP APP.
12/11/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000* CORRIDOR FROM WEST WALL OF LABOR ROOM
12/09/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ 1) GROUND ELECTRODE AT TEN STAKE 1/0 STABLED INTO AND OUT OF CIRCULAR BASE VERIFIED 2) MECH ROOM, ROOM 108A, 108 JANITOR CLOSET APPROVED
12/03/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ UNDERGROUND RT ROOMS 105, WEST TRIANGLE OF ROOM 112 - APPROVED.
11/25/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ 1) FIRE ALARM, LIGHT CU. AND OUTSIDE/LITE 2) BETWEEN POOL STORAGE AD POOL EQUIPMENT 3) L-2 FEEDER, IMCS, AND FIRE ALARM COMPLETE TO EL. ROOM P2-15 4) L-2TO T-2, T-2 TO P-2, P-2 TO P-3, P-2 TO P-4 AND L-2 TO MCC-2
11/20/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ 1) EMCS-CAPLETE 4" FEEDER MCC FEEDER P19, P111. UNDERGROUND APPROVED. ONE LINE OK FOR POLE AREA ELECTRICAL
11/14/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ EMS CONDUIT COMPLETE FROM EL. ROOM TO METER.
11/13/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000*/ (1) 4" L2 FEEDER PANEL FROM SES TO ELECTRIC ROOM UNDERGROUND APPROVED. 2/0 BORE CU. 5FT DEEP FROM SES TO TEL BOARD ROOM. (1) 3/4" SLEEVE MANAGMENT PARTIAL.
11/12/2003 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection 0000* 4" CONDUIT FROM EXSIS VAULT TO FILE ROOM 108 APPROVED. 1" CONDUIT HOME RUM <2-11