Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T02CM00606
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2002 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ 1) YOU CAN INSTALL TEMP PRESSURE RELIEF LINE IN LATER I GUESS 2) DRYER DUCT AND DRYER POWER SOURCE ARE ON OPPOSITE SIDES OF WASHER ? 3) STUCCO LATH NOTE: A. YOU NEED A WEEP SCREED B. YOU NEED TWO LAYERS OF GRADE "D" PAPER C. AT FINAL YOU NEED A STUCCO CARD | |
09/06/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) BATHROOM OUTLET TO BE ON IT'S OWN 20 AMP #12 GA. WIRE, PROTECT WIRE FROM SHEETROCK NAILS 2) NEED EXHAUST FAN AND DUCT TO EXTERIOR 3) NEED TEMP PRESSURE RELIEF LINE FOR WATER HEATER 4) VENT FOR DRYER 5) MAKE SURE B BOARD HTRS ARE ON SEPARATE CIRCUIT SIZED TO AMPS ON HTR LABEL 6) LOOSE ROMEX AT BACK DOOR HANGING FROM CEILING? 7) SEWER OK TO COVER |