Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T02CM00592
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2002 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
04/05/2002 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) WATER HEATER FLUE REQUIRES MINIMUM 1" CLEARANCE 2) REPLACE BANG PLATES AT ELECTRIC HOME RUNS WITH FULL LENGTH FHA STRAPS 3) FIREPLACE FLUE REQUIRES MINIMUM 1" CLEARANCE 4) MAX DEPTH OF NOTCH IN BEARING 2 X 4 WALL IS 7/8" 5) DRYER VENT MUST EXTEND TO EXTERIOR |