Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/02/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/01/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 03/29/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 03/27/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL OFF ROOF PANEL NORTH OF REAR RIDGE 2) STRAP ALL NON CABIN TIED TOP PLATES AT CORNERS AND FRONT DOOR 3) STRAP CORNERS OF TRUSSES DOWN TO KINGS 4) NAIL BIRD BOARDS 5) NAIL OFF REAR SHEARWALLS-NAILS OR STAPLES NOT BOTH |