Permit: T02CM00563

Parcel: 141284010


Addresses:

9053 E LIPPIA ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
10/18/2002 ROOF NAILING Approved IVRS - Inspection 0000*
10/15/2002 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) ROOF: THERE ARE 4 PIECES OF OSB, ON TH UPPER ROOF, TAHT ONLY COVER ONE RAFTER BAY. 2 BAY COVERAGE IS THE MINIMUM, OR THE 2 UNSUPPORTED EDGES OF EACH PIECE, MUST BE BLOCKED (2X) UNDERNEATH AND NAILED OFF THROUGH OSB 2) FRAME: IF THE ANCHOR BOLT, AT THE EAST END OF THE SOUTH WALL IN THE FIREPLACE ROOM, CANNOT BE TIGHTENED, WITH RED HEAD MUST BE INSTALLED 3) MECH: THE 3 FLUE STABLIZER STRAPS MUST BE SECURED. THERE IS OSB, ABOVE THE FLUE CEILING COLLAR, THAT MUST BE CUT BACK FOR 2" CLEARANCE TO FLUE 4) FRAME: SHIM PATIO DOOR AND SOUTH WINDOW HEADER CRIPPLES