Permit: T02CM00562

Parcel: 133371770

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/30/2002 FRAMING Approved IVRS - Inspection 0000*
05/29/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) BLOCK STUD BAY BETWEEN COMBUSTION/ RELIEF VENTS 2) HEADER OFF STUD UNDER STOVE VENT AND SEAL CUT FIREBLOCKS AT SAME 3) BANG PLATE STUD NEXT TO DRYER VENT FOR WIRE 4) NAIL OFF OSB AROUND SOUTH BATH MED. CAB. 5) CLEAN COMBUSTIBLE (WOOD CHIPS) OFF FIREPLACE FIRE BOX BEFORE SHEET ROCK 6) DRYER VENT RUN IS TO LONG (25' MAXIMUM;-5' FOR EACH 90 DEGREE+-2.5 FOR EACH 45 DEGREE)