Permit: T02CM00533

Parcel: 12402008A


Addresses:

1801 E 1ST ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/11/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ 1) YARDWATER OK TO COVER 2) CLOSET FLANGES 2ND FLOOR OK, THIS COMPLETES INTERMEDIATE
08/28/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/1) FIRST FLOOR CLOSET FLANGES OK.
08/27/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/1) ALL OF THE CLOSET FLANGES ON THE FIRST FLOOR NEED TO BE INSTALLED SO I CAN INSPECT.
08/26/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/1) CLOSET FLANGES NOT READY FOR INSPECTION.
07/14/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) PVC DWV THRU ROOF FROM 2ND FLOOR-OK, WATER TEST-OK 2) COPPER WATER PIPING-OK, PRESSURE TEST-OK 3) THIS COMPLETES 2ND FLOOR INTERMEDIATE EXCEPT CLOSET FLANGES AND SHOWERS
07/10/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000* NOT READY FOR INSP
07/09/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ WATER PIPING IN LAUNDRY ROOM OK. OK TO COVER WALLS IN THIS AREA.
07/02/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) WILL NEED TO SEE ALL CLOSET FLANGES 2) ROOMS #120, 121, 122, 119, 118, 117 116, 115, 114 AND 113. COPPER OVERHEAD AND IN THE WALLS-PVC IN THIS AREA ALSO, OK TO COVER INCLUDING UPSTAIRS WASTE
07/01/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) LOW PRESSURE GAS TO LAUNDRY ROOM OK PRESSURE TEST OK 2) OK TO COVER
06/29/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) LOW PRESSURE GAS TEST OK-NEED TO SEE PIPING IN LAUNDRY ROOM 2) 2ND FLOOR WATER MAINS IN CORRIDOR TO ISLOATION VALVES-OK 3) PVC DWV THRU ROOF FOR ROOMS 16, 17, 2008 AND 209-OK AND UNDER FLOOR FOR #216 AND 217 WATER TEST-OK
06/18/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) WATER AND GAS IN CORRIDOR #112 COMPLETE-PRESSURE TESTS OK GAS #65 WATER #100. OK TO COVER HALLWAY 2) GRADUATE SUITE #124 INSTALLED PER APPROVED REVISED PLAN 3) 2-3" ROOF DRAINS FROM 2ND FLOOR OK 4) UNDERFLOOR PLUMBING FOR #204, #205, #206 AND #207 OK. WATER TEST OK. OK TO COVER
06/17/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
06/04/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) OK TO COVER WALLS ONLY IN ROOM 103 2) TEST OK DWV, COPPER AND WATER OVERHEAD WATER LINES IN HALLWAY SEE PLAN P1.1 FOR HI LIGHT AND DATE 3) GAS LINE ROOM #107 IN WALL AND STUB OUT 4) TEST OK TO LAUNDRY ROOM 5) EXTRA FLOOR SINK IN ROOM 6) FLOOR SINK FOR ICE MAKER. PLEASE PROVIDE APPROVED REVISED PLAN 7) TEST OK AT THIS TIME
06/02/2003 PLUMBING - INTERMEDIATE Partial Approval 1) COPPER OVERHEAD IN KITCHEN AREA, SERVING AREA, BASEMENT JANITOR CLOSET AND OVER HEAD FOR LAUNDRY 2) OK-TO COVER
05/22/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*5 AREA DRAINS AND TWO ROOF DRAINS WATER TEST OK OK TO COVER.
2.) BASEMENT LAUNDRY ONLY 24 DRU ALLOWED ON 2" VENT.
3.) BASEMENT MOP SINK VENT OK
4.) KITCHTEN & SERVICE AREA PVC DWV OK WATER SUBJECT TO TEST OK TO COVER WALLS.
04/28/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*TWO ROOF DRAINS IN SOCIAL AREA #105 NOW DUMP INTO COURTYARD REVISE PLAN TO REFLECT INSTALLATION.
2.) OK TO COVER WALLS SUBJECT TO REVISED PLAN.
04/17/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*ALL BASEMENT OVER HEAD PIPING UP THROUGH TO FIRST FLOOR NOW COMPLETE. SUMP EJECTOR OK, NEED TO SEE EJECTOR VENT TO ABOVE FIRST FLOOR.
04/14/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1ST FLOOR KITCHEN AREA INCLUDING SANITARY SEWER AND GREASE WASTE OK.
WATER TEST OK.