Permit: T02CM00517

Parcel: 111081710


Addresses:

2475 N HASKELL DR


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T02CM00517

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/19/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
09/17/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*NOTES VIOCE STREAM MUST REMOVE 6 & 6 BUILDERS OF PERMIT, 6 & 6 BUILDERS NOT CONTR. DOING WORK. 2.) EXPOSE GROUNDING SYSTEM FOR INSPECTION. 3.) REMOVE NEUTRAL BONDING AT SECOND DISC. SW. 4.) USE BOND BUSHINGS WHERE USING CONCENTRIC KO'S TO EQUIP ON ROOF. 5.) NEED VERIFICATION OF L-11 LICENSED CONTR. DOING ELECTRICAL INSTALL, NAME, LICENSE # PHONE#>