Permit: T02CM00481

Parcel: 141014570

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T02CM00481

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/14/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
05/13/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) WEST WALL BROKEN EYE BROW ON EXHAUST FAN 2) REAR HOSE BIB MISSING ANTI-SIPHON 3) SOLDER BOTH 3/4" 90 DEGREE EAST WALL 4) NEED GAS LOCK AT REAR GAS LINE 6) INSTALL CONDENSATE TRAP 7) GROUND, NEUTRAL, REVERSED AT GARAGE 8) RAISE DISPOSAL LINE ABOVE FLOOD RIM 9) FINISH GAS, AND CONNECTIONS AT FIREPLACE 10) PLEASE HAVE CONCRETE CERTIFICATE, INSULLATION CERTIFICATE AND STUCCO CARD WITH PERMIT CARD
04/29/2003 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) PTR LINE SHALL DISCHARGE DOWNWARD 2) ACCESS TO A/C 3) COMPLETE FIREPLACE VENEER? 4) OK TO STOP FURNITURE IN GARAGE AND HOUSE KEEP AWAY FROM WALLS