Permit: T02CM00473

Parcel: 129063250


Addresses:

2713 E 21ST ST

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
03/18/2004 BUILDING - PROGRESS Approved IVRS - Inspection 0000*
02/12/2004 BUILDING - PROGRESS Partial Approval IVRS - Inspection 0000*/ 1) ELECTRIC TESTER SHOWS OPEN GROUND ALL ELECTRICAL OUTLETS 2) NO PERMIT CARD, TO SIGN, HOME OWNER NOT ISSUED 3) OK TO BURY WATER LINE AND HCS TRENCH
12/04/2003 BUILDING - PROGRESS Denied IVRS - Inspection 0999*/ 1) OVER 180 DAYS HAS ELAPSED 2) PERMIT HAS EXPIRED 3) RENEW PERMIT 4) THEN RECALL FOR RE-INSPECTION
04/18/2003 BUILDING - PROGRESS Denied IVRS - Inspection 0999*/ 1) INSTALL WATER HEATER PRESSURE/TEMP RELIEF LINE TO EXTERIOR 2) INSTALL SMOKE DETECTOR BEDROOM 3) BEDROOM TO HAVE HEAT SOURCE 4) INSTALL DRYER 220V OUTLET AND DRYER EXHAUST VENT TO EXTERIOR 4) INSTALL 220V OUTLET RANGE 5) RANGE REQUIRES 4 WIRES ALSO DRYER 6) GROUNDS AND NEUTRAL WIRES TO BE SEPARATED AT SUB PANEL 7) INSTALL BLANK PLATES SUBPANEL ALL UNUSED OPENINGS AND MAIN PANEL 8) INSTALL EXTERIOR ANTI-SIPHON EXTERIOR HOSE BIBS 9) UNCOVER ALL TRADES COVERED WITHOUT INSPECTION 10) ELECTRIC TESTER SHOWS OPEN GROUND ALL ELECTRIC OUTLETS
04/17/2003 BUILDING - PROGRESS Denied IVRS - Inspection 0920*/ 1) NO ONE HOME, NO ACCESS 2) PLEASE RESCHEDULE
11/08/2002 BUILDING - PROGRESS Denied 1) WINDOW A/C CORD SHALL BE RATED TO BE EXPOSED TO WEATHER 2) BREAKER PANEL SHALL HAVE 30" WIDE 36" CLEAR IN FRONT OF PANEL 3) SMOKE DETECTOR MISSING AS PER PLAN 4) ALL PLUMBING COVERED WITHOUT INSPECTION, MUST BE EXPOSED TO VERIFY ALL CONNECTIONS 5) REVISE PLAN TO REFLECT PROPOSED HEATING TO EACH ROOM 6) TERMINATE DRYER WIRES IN APPROVED BOX 7) ALL ELECTRIC CONDUIT SHALL BE WATER PROOF WHEN EXPOSED TO THE WEATHER
07/31/2002 BUILDING - PROGRESS Denied IVRS - Inspection 0999*
07/31/2002 BUILDING - PROGRESS Partial Approval 1) SLOW PROGRESS