Permit: T02CM00450

Parcel: 136012410


Addresses:

8032 E SNAKEROOT DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM00450

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/14/2002 FRAMING Approved IVRS - Inspection 0000*
03/12/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) CONDENSATE LINE NOT COMPLETE 2) FURNACE FLUE MUST EXTEND 6" BELOW CEILING 3) FIREBLOCKING AT ENTRANCE 4) NEED 30" ABOVE ATTIC ACCESS