Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/01/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/04/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SAME AS LAST |
| 03/12/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) A.B.'S AT GARAGE SHEAR 2) SHEAR WALLS NEED TRANSFER (NOT ON PLAN)3) MISSING SHEAR AT NORTHWEST CORNER 4) POST UNDER BEAM AT STAIRS 5) WIRES AGAINST TRUSS GANG PLATES |
| 03/11/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 03/06/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) FINISH PLUMBING/GAS LINE 2) A.B. IN GARAGE SHEAR 3) EXTEND SHEARWALL TO ROOF DECK AND FLOOR DECK IN GARAGE (SHEAR TRANSFER) 4) NEED WINDOWS INSTALLED 5) 2ND FLOOR TOILET FLAT VENT HAS NEGATIVE PITCH 6) CHECK ALL BOTTOM PLATES FOR A/B 7) #5 SHEAR A.B. AT 24" WEDGE ANCHORS OK 2" IN FROM EDGE 8) FLU CONCRETE TUB BLOCK OUTS 9) POST TO FLOOR CONNECTION FILL IN WITH NEXT BLOCK BETWEEN FLOOR |