Permit: T02CM00404

Parcel: 11942002C


Addresses:

4503 S MISSION RD

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/19/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) MUST PROVIDE TRAFFIC RATED C.O. COVERS AND FEMALE COUPLINGS WITH PLUGS ON ALL C.O. TO GRADE. 2) MUST INSTALL A 2" BACKFLOW PREVENTER BY METER FOR POTABLE SUPPLY - SEE SEC 610.2 94 UPC. 3) MUST PROVIDE VACUUM BREAKERS AT ALL HOSE BIBS.