Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T02CM00366
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2002 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000* | |
05/21/2002 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*1.) NEED TO SEE WATER HEATER VENT FINISHED 2.) PROVIDE MIN 1" CLEARANCE AROUND WATER HEATER FLUE PIPE. 3.) CONDENSOR FOR FREEZER OVERFUSED. 20 AMP IS MAX. FUSE SIZE 4.) SUPPORT REFER LINES ON ROOF. 5.) RAISE WATER HEATER VENT 2' ABOVE AIR INTAKE ON AC UNIT. |