Permit: T02CM00274

Parcel: 141013320


Addresses:

5128 S ZENITH WY


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM00274

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/09/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/08/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CANNOT LOCATE GARAGE PLAN
05/22/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CHECK EDGE NAILING OF ALL SHEAR WALLS SW2 6" ON CENTER AND SW3 4" ON CENTER, ADD ADDITIONAL NAILS AS NEEDED 2) CHECK ROOF NAILING ABOVE RED PAINT MARKS ON FLOOR 3) SHIM JACK STUDS UNDER HEADERS MARKED IN RED 4) REMOVE WIRES AWAY FROM RECESSED FIXTURES IN HALL 5) EXHAUST DUCT FROM LAUNDRY ROOM IS SEPARATE IN MIDDLE OF ITS RUN TO OUTSIDE 6) EXHAUST DUCTS FROM LAUNDRY MASTER BATH AND MASTER BATH, WATER CLOSET ROOM NOT CONNECTED TO OUTSIDE