Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T02CM00239
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2002 | PLUMBING - INTERMEDIATE | Approved | ALL CORRECTIONS MADE OK 2.) OK TO COVER ALL AREAS. | |
09/10/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) VENTS MUST RISE VERTICALLY TO A POINT NOT LESS THAN 6" ABOVE FLOOD LEVEL BEFORE OFFSETTING HORIZONTALLY. | |
09/08/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*CHECK WET VENTING OF AW ABOVE LAUNDRY TUB WET VENTED SECTION TO BE ONE PIPE SIZE LARGER THAN TRAP OF UPPER FIXTURE 2.) CLOSET FLANGES OK 3.) PEX OK 4.) GAS OK PRESSURE TEST OK 5.) SHOWER REPAIR OK. | |
08/28/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) HAVE PLUMBER REVIEW NOTES LEFT WITH GENERAL CONTRACTOR CONCERNING CORRECTIONS 2.) MAKE CORRECTIONS AND RECALL FOR INSPECTIONS. |