Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM00208
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/29/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
08/27/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) SECURE ELECTRIC 6" FROM BOXES 2) BLOCK MECHANICAL AIR RETURN 3 SIDES 3) PROVIDE WATER TEST ON DWV SYSTEM 5) STRAP OR CLIP INTERIOR BEARING WALL AT RIDGE BEAM SUPPORT | |
08/13/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) BLOCK DEFUSER BOOTS 3 SIDES 2) PEX PLUMBING NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 3) FIREBLOCK FURRED OUT WALL AT MASONARY WALL TOP 4) BATH DUCT NOT CONNECTED 5) SUPPORT NORTH END OF RIDGE BEAM 6) BEDROOM WINDOWS MUST HAVE RELEASABLE SECURITY BARS 7) SUPPORT 1" GAS LINE AT 10' ON CENTER 8) GAS LINE MUST BE ELECTRICALLY BONDED IN EXPOSED LOCATION WITH #4 WIRE 9) FIRE STOP RANGE CHASE 10) PROVIDE 22 X 30 ATTIC ACCESS 11) PROVIDE A/C CONDENSATE DRAIN 12) WATER HEATER T&P LINE MUST EXHAUST OUTSIDE 13) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF WALL SURFACE |