Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 06/21/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL GAS VALVES MUST BE CAPPED |
| 06/18/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999$/ 1) GFCI IN NORTH BATHROOM WILL NOT TRIP USING GFCI TESTER 2) CAULK AROUND THE BASE OF BOTH TOILETS 3) ROUND DUCT FOR FURNACE/COOLING MUST HAVE A MINIMUM OF 3 SCREWS AT EACH JOINT PRIOR TO TAPING 4) CANNOT USE FLEX PIPE ON WATER HEATER TPRV DISCHARGE LINE. MUST BE RIGID COPPER TYPE M OR EQUIVALENT SOFT COPPER ALSO NOT ALLOWED |