Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T02CM00137
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2002 | ELECTRIC - INTERMEDIATE | Approved | ||
04/24/2002 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*COVER TOP SILL (FIREWALL) WITH DRYWALL. MC CABLE NOT SECURED PER N.E.C. HANDY BOXES ARE TOO SMALL FOR OF THE BOX ABOVE SOUTH WINDOW & THE GARAGE DOOR OPENER. USE GROUNDING SCREWS PER NEC. STANDARD MACHINE SCREWS ARE NOT ALLOWED USE J-BOX FOR TRANSITION BETWEEN MC CABLE & PVC. |