Permit: T02CM00121

Parcel: 13316037K

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
01/30/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
01/28/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) HORIZONTAL WASTE LINE EXCEEDS 135 CHANGE OF DIRECTON WILL REQUIRED A C.O. AFTER THE 1ST 135 2.) SOIL WATER TEST WAS DOWN. 3.) P-3 IS A MOP SINK AND IS A 2 FIXTURE UNIT FUXTURE. THIS FIXTURE WILL REQUIRE A 2" DRAIN MIN. 4.) NO P&T DRAIN INSTALLED @ THIS TIME 5.) CAN NOT MIX MATCH MATERIALS ON WATER DISTRIBUTION. EITHER ALL COPPER OR ALL PEX.