Permit: T02CM00116

Parcel: 10713242L


Addresses:

307 E JACINTO ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/19/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
07/08/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) WINDOW WITHIN 24" OF DOOR WAY MUST BE SAFETY GLAZED 2) COMPRESSION FITTINGS ON 3/4" PEX NOT ALLOWED ENCLOSURE IN WALLS AND CEILINGS IMPROPER CONNECTIONS THROUGHOUT 3) SEAL/BACK GROUT FLOOR UNDER TUB 4) LEAK AT WATER HEATER 5) NO WATER HEATER T&P LINE-MUST EXTEND OUTSIDE 6) INTERMIXING OF PEX PRODUCTS NOT ALLOWED 7) SMOKE DETECTORS MUST BE AT LEAST 36" FROM AIR REGISTERS 8) TOILET MUST HAVE 2" WASTE VENT 9) LAUNDRY NOT VENTED-WASTE TRAP TO HIGH. STRAPED WRONG
07/01/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*