Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date |
Description |
Inspector |
Results |
Comments |
| 05/09/2002 |
BUILDING PRE-SLAB |
|
Approved |
IVRS - Inspection 0000* |
| 05/03/2002 |
BUILDING PRE-SLAB |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST ON SEWER LINES 2) PLANS/PERMITS NOT ON SITE 3) NO ANSWER TO KNOCKING ON DOOR AT 8:45 AM |
| 04/30/2002 |
BUILDING PRE-SLAB |
|
Denied |
IVRS - Inspection 0999*/ 1) MANY SEWER LINES FITTINGS MISALIGNED AND STRAINED 2) SANITARY "T" FITTINGS CANNOT BE USED IN SEWER OR DRAIN LINES 3) SEWER LINES MUST BE AT LEAST 12" BELOW GRADE AT EXIT OF BUILDING 4) W/C NOT PROPERLY VENTED 5) REDUCING BUSHING CANNOT BE USED IN SEWER OR DRAIN LINE 6) HOLDOWNS REQUIRE REBAR ABOVE HOOK |