Permit: T02CM00039

Parcel: 132169170

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/08/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1.) ABS DWV OK WATER TEST OK 2.) COPPER WATER PIPE OK PRESSURE TEST OK 3.) CLOSET FLANGES OK 4.) OK TO COVER.
03/06/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999* 1.) ABS TO BE SUPPORT MAX 4' HORIZONTAL 2.) REQUIRE WATER TEST ON INTERIOR DWV ABS 3.) CLOSET FLANGES OK 4.) DON'T FORGET TO DELETE SHOWER FROM APP PLAN. 5.) COPPER WATER PIPING OK.