Permit: T02CM00010

Parcel: 11904609A


Addresses:

438 W AJO WY

Inspection Status: Closed

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/08/2007 BUILDING - FINAL Closed
07/30/2003 BUILDING - FINAL Denied IVRS - Inspection 0999* ADA PARKING ISSUE NEVER RESOLVED. 2) AREA IS NOT USED FOR CUSTOMER PARKING. 3) RESIDENCE ATTACHED TO OOFICE IS BEING USED FOR STORAGE. PERMIT FOR THAT AREA MAY BE EXPIRED, BUT NO WORK IS BEING DONE .
06/02/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) NO ADA PARKING/NO PLAN REVISION
05/30/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
04/04/2003 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*1.) OK RELEASE OF POWER.
2.) APA PARKING ISSUES STILL NEED TO BE RESOLVED. FOLLOW UP 5/30/03
03/13/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*you need ada parking.
please revise plan to provide for auto sales office
2.) ramp at entrance may not slope more than 1:12 curb ramp.
3.) you need permits for new work in residence unit #2.
03/12/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
06/21/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*
1.) HANDICAPPED WATER CLOSET TO BE CENTERED 18" TO SIDEWALL.
2.) HANICAPPED TOILET SEAT MUST HAVE SPLIT FRONT
3.) WATER CLOSET GRAB BARS NEED TO BE 36" AT REAR, 4'2" AT SIDE. SEE PLAN DETAIL.
4.) WRAP LAVATORY TRAP.
5.) PROVIDE PARKING SPACES PER PLAN
6.) PLAN CALL FOR NEW PORCH.
7.) PROVIDE FIRE BARRIER AT OCCUPANCY SEPARATION
8.) HANDICAPPED PARKING SPACES NOT PROVIDED.
9.) DOORS ARE TO BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF KEYS OR SPECIAL KNOWLEDGE OR SPECIAL EFFORT.
10.) INSTALL COVER PLATES ON ELECTRICAL BOXES.
11.) BARS OVER BEDROOM EGRESS WINDOW MUST BE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL OR FORCE GREATER THAT WHICH IS REQUIRED FOR NORMAL OPERATION OF THE ESCAPE AND RESCUE OPENING.
06/07/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*BLD INSP. TO BE LAST INSPECTION.