Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 12/12/2002 |
POOL/SPA FINAL/BARRIER |
|
Approved |
IVRS - Inspection 0000* |
| 11/26/2002 |
POOL/SPA FINAL/BARRIER |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL HEATER TEMP/PRESSURE RELIEF 2) WINDOW SCREENS TO HAVE NON-REMOVABLE HEADS 3) REAR DOUBLE DRIVE GATES NOT TO CODE 4) CHAIN LINK FENCE CANNOT BE CLIMBABLE 5) CANNOT VERIFY GAS PIPING UNDER RAISED WOOD FLOOR OF HOUSE (CRAWL-HOLE TO SMALL) 6) GAS LINE NOT RUN PER PLAN 7) MAXIMUM 4" GAP BETWEEN VERTICAL BARS (IRON FENCING) 8) SUPPORT GAS PIPING UNDER FLOOR MAXIMUM 8' SPACING 9) GALVANIZED GAS PIPING TO BE A MINIMUM OF 6" ABOVE GRADE 10) ENCLOSURE NOT TO PLAN OR CODE 11) GATE LATCHES NOT PER CODE 12) SUPPORT ELECTRIC CONDUIT MORE RIGIDLY 13) BLOCK WALL EAST SIDE NOT MINIMUM HEIGHT |