Permit: T02BU02565

Parcel: 118020720


Addresses:

1400 S SHANNON RD

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/02/2003 BUILDING - FINAL Approved
12/05/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*
1.) SCREEN WALL AT FRONT YARD IS BEING USED TO RETAIN UP TO 2' OF EARTH. IT WAS NOT BUILT AS A RETAINING WALL.
2.) MAX, HEIGHT OF RETAINING PORTION SHOULD BE 3' 6", THE EAST WALL EXCEEDS THAT.
3.) MAX HEIGHT OF SCREEN WALL IS 6' ABOVE RETAINING. THAT IS EXCEEDED BY 2' AND MORE IN SOME PLACES.
4.) PREGROUT INSPECTION FOR SCREEN WALL AND FOR ADDED HEIGHT OF RETAINING WALL WAS NEVER DONE.
5.) ASPHALT EMULSION, PER GRAVEL & FILTER FABRIC NOT INSTALLED PER PLAN.
10/23/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*