Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
10/04/2002 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
10/03/2002 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*NO PLANS @ SITE FOR RETAINING WALL WITH FENCE ON TOP. 2.) BE AWARE THAT EXCESSIVE LOOSE DEBRIS IN FOOTERS WILL RESULT IN A DENIAL. 3.) THE BOTTOM OF A FOOTING MAY NOT SLOPE MOVE THAN 1' IN 10'. 4.) 3" CLEARANCE FROM REINFORCEMENT TO EARTH IS REQUIRED.