Permit: T02BU02261

Parcel: 136327110

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
12/12/2002 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection 0000*
12/06/2002 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection 0000*/ 1) IRC CODE SEC. EA1069.2 # 8 INSULATED CU. BOND FROM J-BOX TO WET NICHE FIXTURE. INSIDE FIXTURE AND AT J-BOX USE POTTING COMPOUND TO SEAL CONDUIT AND COVER WIRE CONNECTION 2) FLUE CAP FOR HEATER 3) ROMEX CONNECTOR FOR CONTROL WIRE IN SUB-PANEL 4) LABEL 2 POLE 30 AMP IN SERVICE 5) ALL WINDOWS IN ENSLOSURE TO HAVE NON REMOVABLE SCREWS, WINDOW OPEN TO A 4" SPACE