Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T02BU02107
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2002 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection 0000* | |
10/23/2002 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection 0999*/ 1) AS I READ SPA/POOL CODE BOOK ( CHAPTER 4 PERMANENTLY INSTALLED RESIDENTIAL SPAS BARRIERS AND ENCLOSURES), A SECUREABLE SPA COVER MAY BE USED FOR A BARRIER AND ENCLOSURE IF ALL THE FOLLOWING ARE MET: WHEN IN CLOSED POSITION, A SPHERE 4" IN DIAMETER IS PREVENTED FROM REASHING THE WATERS SURFACE, THE COVER IS DESIGNED TO SUPPORT A STATIC LOAD OF 100 POUNDS, THE SPA WIDTH OR DIAMETER DOES NOT EXCEED 8' (EIGHT FEET), OK; #2 NEED MANUFACTURER SPECIFICATIONS TO VERIFY SAME, SPA DIAMETER MEASURES 8' 2"- 8' 3" (OVER MAXIMUM ALLOWABLE) | |
10/16/2002 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection 0000*/ 1) SPA COVER SUBSTITUES FOR BARRIER, HOWEVER, IT DOES NOT SUBSTITUE FOR THE ENCLOSURE, WHICH SEPERATES THE PUBLIC FROM THE BACK YARD THERFORE, THOSE GATES MUST BE SELF CLOSING AND LATCHING | |
10/15/2002 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection 0000*/ 1) ALL GATES IN ENCLOSURE TO BE SELF CLOSING, SELF LATCHING 2) NEED MANUFACTURERS SPECS ON SPA COVER |