Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T02BU02014
Inspection Description - GRADING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2007 | GRADING - FINAL | Approved | ||
| 10/31/2007 | GRADING - FINAL | Not ready for Inspection | MET WITH THE ENGINEER OF RECORD TO DISCUSS PUNCH LIST FROM FINAL GRADING INSPECTION DATED 4/16/07. HE STATED THAT AN AS-BUILT WILL BE COMPLETED THIS WEEK TO SHOW ANY CHANGES MADE TO THE ORIGINAL GRADING PLAN AND STORM DRAIN PLAN, A COPY WILL BE GIVEN TO MATT FLICK AND A COPY WILL BE GIVEN TO ME FOR ARCHIVE. FINAL GRADING INSPECTION WILL BE CALLED IN THIS WEEK. |
|
| 04/16/2007 | GRADING - FINAL | Denied | 1) PROVIDE A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD STATING THAT ALL DRAINAGE STRUCTURES AND ANY RET/DET BASINS ON SITE WERE BUILT IN ACCORDANCE WITH THE APPROVED GRADING PLAN. 2) PROVIDE AN AS-BUILT DRAWING SHOWING ANY SIGNIFICANT CHANGES MADE TO THE APPROVED GRADING PLAN. THE DRAWING MUST BE STAMPED BY AN ENGINEER AND APPROVED BY THE CITY OF TUCSON. 3) DRAINAGE CHANNEL SIDE SLOPES ON SOUTH WEST CORNER OF SITE ARE GREATER THAN 3:1 AND CHANNEL IS DEEPER THAT TWO FEET. THE ADJACENT SIDEWALK MUST HAVE SAFETY RAILING OR SIDE SLOPES MUST BE RE-WORKED. |