Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T02BU01965
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/21/2002 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection 0000* | |
08/14/2002 | POOL/SPA PRE-GUNITE | Denied | IVRS - Inspection 0999*/ 1) EXPOSE GAS PIPE JOINTS FOR INSPECTION. JOINTS MUST BE TAPED. OK TO BACKFILL REMAINDER. PRESSURE ON 8/14 2) INSTALL TPR VALVE ON HEATER OR PROVIDE SPECS THAT STATE OTHERWISE 3) CLEANOUT WASHED IN DIRT AT NORTHEAST END OF POOL 4) ADDRESS POOL/SPA PROXIMITY TO NORTH RETAINING WALL NOTE: DECK RAILING MUST BE BONDED |