Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02BU01894

Parcel: 141112970


Addresses:

8500 E HODGMAN PL


Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T02BU01894

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
11/27/2002 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection 0000*/ 1) NON-SELF CLOSING HALF OF DOUBLE GATE HAS BEEN WELDED SHUT
11/25/2002 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection 0999*/ 1) A LOCK IS NOT ACCEPTABLE FOR THE DOUBLE GATE
11/18/2002 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection 0999*/ 1) W.I. BARRIER CANNOT HAVE OPENINGS UNDER IT GREATER THAN 4" 2) DOUBLE GATE, LEADING TO FRONT YARD, IS NOT ACCEPTABLE AS A POOL BARRIER
11/15/2002 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection 0999*